Xray machine specification Stationary anode tube without oil and aluminium cap 60ma/100ma/300ma/500ma 125 kvp 100 amp mcb with electrical mainswitch and fuse Xray generator single phase Two pulse Wooden x ray table Column stand Lintel metal piece to fix column stand Wooden xray table that can be tilted using metal parts with sun mica sheet Bucky to keep x ray casette No grid Ht transformer with plastic or wooden encapsulation with high current ht rectifier Single focus Chest stand column One second timer adjust kv and ma only Voltimeter input 230 v Voltimeter output of autotransformer and kv selection Ammeter in input Ammeter in series output of autotransformer Metal cabinet control panel painted white. Column stand painted white Ht receptacle to be fitted without petroleum jelly. No flouroscopy it was foolish? Any make x ray tube whichever cheaper Beeper on exposure relay on Acessories X ray casette 5 sizes X ray film a 4 hundred sheet Developer and fixe...
Crt tv repair Open the tv Touch lot knobs with tester Now adays lot without shock Fit the audio vedio cable tv or dish input Adjust the lot with hand with channel on and tune brightness and contrast Old crown tv at edapally home lot having shock father tried to adjust and had heart attack i think i was in chennai I am sorry He was cremated at native place peringode as per my memory. Cut and join tv wire apply insulation tape Apply insulaton tape on on off bed switch wire joint There are two plugs on crt tv board one for 230 volt one for crt Check resistance check pcb wiring circuit Adjust the potentiometer on board for image horizontal size. Slow down your tv repair Very high voltage inside Epram raman had heart attack tv shock It is not easy to change crt tv kit Component level not easy Indchem Truscope two component level service no complaint till now Thekiniyedam krishnan had shock heart problem He not having any problem now. Tv i repaired had some problem S...
Minor equipment repair manual Instrument sterilizer Change kettle element Remove calcuim deposit with tezaab Change plug ceramic connector wire Washer with kettle element Bp apparatus Change bp bulb and bladder Bp bulb with valve Change broken glass tube Fill mercury if lost mercury Horizontal and vertical autoclave Change geyser element Microscope Clean lens with spirit eyepiece and objective Change any broken objective I suggested may weld microscope to avoid collision Repair microscope lamp Colorimeter Caliberate blank Change fused lamp must be 6v 10watt halogen same for analyser also Semi auto analyser Change tubing Change fused lamp Order test kits Order pm kits Wash flowcell after each test by aspirating distilled water May remove flowcell Keep test tube in flowcell container Fit computer ribbon connector for filter wheel Xray machine Change xray machine control panel fuses Remove two main switch fuses make single phase Remove grid Disengage bucky motor Make wood...
Comments
Post a Comment